Schneider Electric TeSys D kontaktor za promenu smera-3P-<=440 V - 40 A AC-3 - 24 V DC kalem;LC2D40ABBE

Schneider Electric TeSys D kontaktor za promenu smera-3P-<=440 V - 40 A AC-3 - 24 V DC kalem;LC2D40ABBE

TeSys D reversing contactor - 3P - <= 440 V - 40 A AC-3 - 24 V DC coil...

Brand: Schneider Electric
Product Code: LC2D40ABBE
Availability: Check availability
VAT-exclusive price: 51.043,00
VAT-inclusive price: 61.251,60

TeSys D reversing contactor - 3P - <= 440 V - 40 A AC-3 - 24 V DC coil

Main
range
TeSys
 
product name
TeSys D Green
 
product or component type
Reversing contactor
 
device short name
LC2D
 
contactor application
Motor control
Resistive load
 
utilisation category
AC-3
AC-1
 
device presentation
Preassembled with reversing power busbar
 
poles description
3P
 
power pole contact composition
3 NO
 
[Ue] rated operational voltage
Power circuit: 690 V AC 25...400 Hz
 
[Ie] rated operational current
60 A (at <60 °C) at <= 440 V AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC-3 for power circuit
 
motor power kW
11 kW at 220...230 V AC 50 Hz
18.5 kW at 380...400 V AC 50 Hz
22 kW at 415 V AC 50 Hz
22 kW at 440 V AC 50 Hz
22 kW at 500 V AC 50 Hz
30 kW at 660...690 V AC 50 Hz
 
motor power HP (UL / CSA)
3 hp at 115 V AC 60 Hz for 1 phase motors
5 hp at 230/240 V AC 60 Hz for 1 phase motors
10 hp at 200/208 V AC 60 Hz for 3 phases motors
10 hp at 230/240 V AC 60 Hz for 3 phases motors
30 hp at 460/480 V AC 60 Hz for 3 phases motors
30 hp at 575/600 V AC 60 Hz for 3 phases motors
 
control circuit type
DC DC low consumption
 
[Uc] control circuit voltage
24 V DC
 
auxiliary contact composition
1 NO + 1 NC
 
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
 
overvoltage category
III
 
[Ith] conventional free air thermal current
10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
 
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
 
rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
 
[Icw] rated short-time withstand current
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
320 A 40 °C - 10 s for power circuit
720 A 40 °C - 1 s for power circuit
72 A 40 °C - 10 min for power circuit
165 A 40 °C - 1 min for power circuit
 
associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
 
average impedance
1.5 mOhm - Ith 60 A 50 Hz for power circuit
 
[Ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
 
electrical durability
2 Mcycles 35 A AC-3 at Ue <= 440 V
0.7 Mcycles 60 A AC-1 at Ue <= 440 V
 
power dissipation per pole
2.4 W AC-3
5.4 W AC-1
 
Front cover
With
 
interlocking type
Mechanical
 
mounting support
Rail
Plate
 
standards
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
 
product certifications
CCC
CSA
EAC
UL
KC
DNV-GL
LROS (Lloyds register of shipping)
 
connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid
 
tightening torque
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
 
operating time
55...65 ms closing
20...120 ms opening (date code >= 17221)
20...80 ms opening (date code >= 18011)
 
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
 
mechanical durability
6 Mcycles
 
maximum operating rate
3600 cyc/h 60 °C
 
Complementary
coil technology
Built-in bidirectional peak limiting
 
control circuit voltage limits
<= 0.1 Uc (-40…70 °C):drop-out DC
0.8...1.2 Uc (-40…60 °C):operational DC
1...1.2 Uc (60…70 °C):operational DC
 
inrush power in W
11 W at 20 °C
 
  • TeSys D LC2D40ABBE

    TeSys D LC2D40ABBE



Similar products:


Schneider Electric TeSys D kontaktor za promenu smera-3P(3 NO)-AC-3 - <= 440 V 18 A - 24 V DC kalem;LC2D18BL

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 24 V DC coil
-
Need to order

(Out of stock)

 
 
17.475,00

Schneider Electric Kontaktor za promenu smera 575VAC 18A IEC;LC2D18BD

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 24 V DC coil
-
Need to order

(Out of stock)

 
 
20.842,00

Schneider Electric Kontaktor za promenu smera 575VAC 25A IEC;LC2D25BL

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V low consumption DC coil
-
Need to order

(Out of stock)

 
 
24.537,00

Schneider Electric Kontaktor za promenu smera 575VAC 25A IEC;LC2D25BD

TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
-
Need to order

(Out of stock)

 
 
26.274,00

Schneider Electric TeSys D kontaktor za promenu smera-3P-<=440 V - 50 A AC-3 - 24 V DC kalem;LC2D50ABBE

TeSys D reversing contactor - 3P - <= 440 V - 50 A AC-3 - 24 V DC coil
-
Need to order

(Out of stock)

 
 
60.816,00

Schneider Electric TeSys D kontaktor za promenu smera-3P-<=440 V - 65 A AC-3 - 24 V DC kalem;LC2D65ABBE

TeSys D reversing contactor - 3P - <= 440 V - 65 A AC-3 - 24 V DC coil
-
Need to order

(Out of stock)

 
 
85.864,00

ELECTRO PNEUMATIC SOLUTIONS DOO

  • Jugoslovenska 2/13A, Čukarica, Beograd
  • Opening Times: Monday - Friday 8am-5pm
  • Telephone:
  • 011 257 1922
  • +381 64 659 66 55
  • +381 62 800 70 44
  • email: office@ep-solutions.rs

linkedin youtube instagram twitter facebook
1
2
3
Compare products Remove all products